Each of the four types of security lighting has its uses, but no one type is good for all applications When designing the system, you need to consider the following areas and lighting requirements (see Table 5-1) The table outlines the minimum amount of illumination needed and provides foot-candles based on
PDF-417 2d Barcode Recognizer In None
Using Barcode recognizer for Software Control to read, scan read, scan image in Software applications.
Paint PDF-417 2d Barcode In Visual C#
Using Barcode creation for .NET framework Control to generate, create PDF-417 2d barcode image in VS .NET applications.
Perimeter Security
PDF417 Generator In VS .NET
Using Barcode maker for ASP.NET Control to generate, create PDF 417 image in ASP.NET applications.
Generating PDF417 In .NET Framework
Using Barcode generator for .NET framework Control to generate, create PDF417 image in VS .NET applications.
the Department of the Army Field Manual 1930 Physical Security FM 3-1930 dated January 8, 2001, supersedes FM 3-19, which was dated March 1979 FM 3-1930, like the older version, is the standard used in the security industry for lighting requirements The foot-candles have not changed from the older to the new edition of the FM The minimum lighting recommendations in the table are based on FM 3-1930 Table 5-2 summarizes the security requirements of the Illuminating Engineering Society of North America These standards are used in numerous local ordinances that call for security lighting as a part of Crime Prevention Through Environmental Design (CPTED) CPTED has gained wide acceptance in a number of communities across the United States and Canada CPTED is the concept of prevention through the build out of the site to reduce the incidence of crime and the fear of crime occurring The ordinances in most communities state that security lighting should not be directed above the horizontal plane of the project The lights should have shields on the fixtures to keep the light from being visible on adjacent properties and roadways The general use of floodlights as a part of the security lighting design is discouraged and may not be permitted Here is an outline of the requirements of some jurisdictions for security lighting The requirements are usually part of an ordinance that outlines all lighting requirements that are acceptable throughout the jurisdiction The ordinances usually are enforced as a part of the building permit process: 1 The illumination from security lighting will not illuminate vertical surfaces on buildings to a level of 8 feet above grade or 8 feet above the bottom of doorways or entries, whichever is greater 2 Poles for mounting security lighting can be no more than 10 feet from the perimeter of the designated secure area
PDF-417 2d Barcode Generator In VB.NET
Using Barcode creator for .NET Control to generate, create PDF 417 image in .NET framework applications.
Barcode Creation In None
Using Barcode printer for Software Control to generate, create bar code image in Software applications.
TABLE 5-2 Illumination tables (foot-candles) permitted for security lighting applications Illuminating Engineering Society
Painting Data Matrix ECC200 In None
Using Barcode encoder for Software Control to generate, create Data Matrix image in Software applications.
Encoding Code 128C In None
Using Barcode drawer for Software Control to generate, create ANSI/AIM Code 128 image in Software applications.
LOCATION FOOT-CANDLES REQUIRED AT LEVEL ON GROUND
Bar Code Generator In None
Using Barcode generation for Software Control to generate, create barcode image in Software applications.
Code 39 Full ASCII Generator In None
Using Barcode generator for Software Control to generate, create Code 3/9 image in Software applications.
Perimeter Fence Buildings Large open areas Entrances Gatehouses Pedestrian walkways and access points
Drawing European Article Number 8 In None
Using Barcode printer for Software Control to generate, create EAN-8 Supplement 2 Add-On image in Software applications.
Bar Code Creator In Java
Using Barcode encoder for Android Control to generate, create barcode image in Android applications.
05 05 20 05 20 10 30 4 6
Barcode Encoder In .NET Framework
Using Barcode creator for ASP.NET Control to generate, create barcode image in ASP.NET applications.
Drawing UPC - 13 In None
Using Barcode maker for Font Control to generate, create EAN / UCC - 13 image in Font applications.
Security Lighting
Encoding Bar Code In None
Using Barcode maker for Office Word Control to generate, create bar code image in Word applications.
Create Code 39 Full ASCII In Java
Using Barcode generation for Android Control to generate, create Code 39 Full ASCII image in Android applications.
3 Perimeter security lights will have motion sensors to activate the lights, since the lights are to be in the off position until the motion sensor is tripped by an intruder within 5 feet of the perimeter 4 The height of the pole on which a security lighting fixture is mounted is usually restricted to no more than 15 to 20 feet, depending on the jurisdiction 5 The illumination tables (foot-candles) permitted for each security lighting application are based on the Illuminating Engineering Society of North America Those jurisdictions that have adopted CPTED use the Illuminating Engineering Society of North America s security lighting standards outlined in Table 5-2 6 The jurisdiction will review and approve the plans for security lighting as a part of the site lighting master plan Lighting requirements for the perimeter fence based on FM 3-1930: 1 Where the perimeter fence is more than 100 feet or more from the building and there is a 100-foot clearance for 100 feet outside of the perimeter fence, the type of lighting recommended is glare projection 2 For what is known as semi-isolated fenced perimeters, where there is not a clear zone within 60 to 100 feet outside the fence, controlled lighting is recommended 3 For perimeter fence lines that are immediately adjacent to buildings, etc, controlled lighting is recommended inside the fence area Lighting needed for illuminating the entrances to the site based on FM 3-1930: 1 Controlled lighting should be used for pedestrian entrances used to and from the site The lighting should provide enough illumination to recognize people and examine ID badges This requires a minimum of 20 footcandles of illumination 2 Vehicle entrances, on the other hand, should have enough illumination to complete a safe inspection of passenger cars, trucks, and freight cars (rail), including the contents 3 Security officer gatehouses usually have a lower intensity of illumination inside the gatehouse, so officers can see approaching vehicles and pedestrians If the illumination intensity inside the gatehouse is too high, the officer will not be able to see out as easily but would be easy to see from the outside Lighting illuminating other areas of the site and property based on FM 3-1930: 1 Vacant land, storage, garages, and parking areas require illumination by controlled lighting of not less than 02 foot-candles