action (locked only when the current is on) units require that you specify the hand when you place the order for the unit. To repeat: Understand that electrical strikes are not just electrical appliances; they are hardware. In the case of Adams Rite strikes, they are made by hardware people, because they know that the hardware has to be carefully matched to its application. Also, realize that when you order a unit for installation, you need to check with the local electrical codes to ensure that you can actually install it. Some jurisdictions may require an electrician to do the job.
Recognize QR In Visual Studio .NET
Using Barcode recognizer for .NET Control to read, scan read, scan image in .NET applications.
Paint Barcode In .NET
Using Barcode encoder for Visual Studio .NET Control to generate, create bar code image in .NET applications.
Installation and procedures
Barcode Scanner In VS .NET
Using Barcode scanner for .NET Control to read, scan read, scan image in .NET framework applications.
Painting QR Code ISO/IEC18004 In C#.NET
Using Barcode creator for .NET framework Control to generate, create QR image in VS .NET applications.
The following section discusses and illustrates some of the procedures required to install a variety of strike units.
Draw QR Code JIS X 0510 In Visual Studio .NET
Using Barcode generation for ASP.NET Control to generate, create QR-Code image in ASP.NET applications.
QR Code JIS X 0510 Printer In VB.NET
Using Barcode generation for .NET framework Control to generate, create QR Code image in .NET framework applications.
Aluminum jam installation (Series 750)
DataMatrix Generation In .NET Framework
Using Barcode encoder for VS .NET Control to generate, create Data Matrix 2d barcode image in .NET framework applications.
Create GS1 DataBar Truncated In Visual Studio .NET
Using Barcode drawer for Visual Studio .NET Control to generate, create DataBar image in VS .NET applications.
1. Prepare the door jamb per Fig. 19.2. 2. Install the mounting clips to the jamb using 8-32 3 8 screws and pressed metal nuts. Leave the screws slightly loose to permit easy alignment of the base assembly and clip. 3. Spacers are provided to assure flush final assembly of the faceplate and jamb. Add one or more spacers between the jamb and mounting clip when the faceplate extends beyond the jamb. When the faceplate sets inside the jamb, you must add spacers between the mounting clip and the electric strike case. See detail A in Fig. 19.2. To attach spacers to the mounting clip, remove the protective coating from the spacer and press to the desired mounting clip surface. Make sure the clearance hole in the spacer aligns properly with the hole in the mounting clip. 4. Using the wire nuts, connect the wires coming from the unit to the wires coming from the low-voltage side of the transformer. 5. Insert the electrical release into the jamb by tipping the solenoid coil into place behind the mounting clip, then drop the unit onto the clips. 6. Attach the unit with the #10 screws and lock washers provided. 7. Attach the faceplate using the screws furnished (8-32 1 4 inch). 8. Secure the screws holding the mounting clips to the jamb. Figure 19.2 also shows the dimensions of the electric door release that would be installed in the aluminum jamb.
Printing Matrix 2D Barcode In .NET
Using Barcode maker for .NET Control to generate, create Matrix Barcode image in VS .NET applications.
Postnet Generation In .NET
Using Barcode generation for VS .NET Control to generate, create Postnet 3 of 5 image in Visual Studio .NET applications.
Replacing an obsolete unit with an electrical strike (model 7510 wood jamb)
Bar Code Reader In None
Using Barcode scanner for Software Control to read, scan read, scan image in Software applications.
Decoding Code 39 Extended In C#
Using Barcode recognizer for Visual Studio .NET Control to read, scan read, scan image in Visual Studio .NET applications.
1. Prepare the jamb to the dimensions shown in Fig. 19.3. Take care to mortise the cut to clear the solenoid.
Code 39 Extended Generator In Visual Studio .NET
Using Barcode printer for ASP.NET Control to generate, create Code 39 image in ASP.NET applications.
DataMatrix Creator In Java
Using Barcode creation for Java Control to generate, create DataMatrix image in Java applications.
DIMENSIONS 1.065 (27.1) In inches and (millimeters) 3 013 000 1.593 (40.5) 1.495 (38.0) 2.6.R. (66.0) 1.250 (31.7) Detail Horizontal centerline of cylinder (A-R .267 (6.8) 4500 series 760 deadlatch) reverse action only (66.0) 1.437 1.50 (36.5) (38.1) 0.4 0.0 1.255 (31.9) 0.10 .625 (15.9) 0.3 .656 (16.7) 010 000 .656 (16.7) 0.3 156R (TYP 4 PLCS) (4.0) 0.15 000 4.875 (123.8) 0.4 0.0 0.10 .625 (15.9) 0.3 8-32 1/2 LG screw Wire nuts Low voltage electrical leads Lockwasher 10-32 screw 8-32 screw
ECC200 Reader In .NET Framework
Using Barcode scanner for .NET framework Control to read, scan read, scan image in .NET framework applications.
Painting ANSI/AIM Code 39 In C#
Using Barcode drawer for Visual Studio .NET Control to generate, create ANSI/AIM Code 39 image in VS .NET applications.
3.370 (85.6)
Barcode Reader In C#.NET
Using Barcode Control SDK for Visual Studio .NET Control to generate, create, read, scan barcode image in .NET applications.
Make GTIN - 12 In C#.NET
Using Barcode creator for .NET Control to generate, create UPC-A Supplement 5 image in VS .NET applications.
2.468 (62.7) 4.870 (123.7) Horizontal center line of electric door release bolt 1.641 (41.7)
015 000 3.375 (85.7) 0.4 0.0
C L SYM
Drill & countersink for 8-32 flat head screw (2 PLCS) Pressed metal nuts Vertical centerline of deadlatch mounting, screws in same plane as electric release mounting screws .875 (22.2) Pressure sensitive spacer
Mounting clip
Figure 19.2 Jamb specifications and installation details for a radial (curved) aluminum door
jamb. (Adams Rite Mfg. Co.)
Electrical Access and Exit Control Systems
2. Using the wire nuts provided, connect the wires from the 7510 unit to the wires from the low-voltage side of the transformer. 3. Insert the electric release into the jamb. Attach this with #10 flat head wood screws.
Replacing the obsolete unit. Unit 002 is used as an example.
1. Remove the 002 unit and disconnect the low-voltage wires. Do not remove the existing mounting clips. 2. Enlarge the jamb cutout by removing 1 4 inch from each side. 3. Using the wire nuts, connect the 7510 wires to the low-voltage side of the transformer. 4. For a flush installation, provide a 1 16-inch spacer between the mounting surface and the face plate. 5. Insert the electric door release into the jamb, and attach with screws. Figure 19.3 also shows the dimensions of the 7510 electrical door release unit.
Installing an electric strike to meet ANSI specifications. Model 7520 is used in the example. Note the molded strip down the center of the door frame in the illustration. Installation is as follows:
1. Prepare the metal jamb to the dimensions shown in Fig. 19.4. 2. Spacers are provided with the unit to assure the flush mounting of the faceplate to the jamb. To use the spacer(s), remove the protective cover and press them to the mounting bracket. Make sure the clearance hole in the spacer aligns with the tapped hole in the bracket. 3. Connect the wires from the unit to the transformer wires. 4. Insert the electric release into the jamb by tipping the solenoid coil into place behind the mounting bracket. Then drop the unit onto the mounting brackets. Attach the unit with the screws furnished. 5. Attach the faceplate.
Installing an electric strike for key-in-knob latch to ANSI specifications. The exam-
ple used is an Adams Rite Model 7540 Unit. 1. Prepare the door jamb as shown in Fig. 19.5. 2. Install the mounting clips using the screws and pressed metal nuts. Leave the screws slightly loose to permit easy alignment of the case assembly and clip. 3. Use the provided spacers as necessary. 4. Connect the wires from the 7540 unit to the low-voltage wires from the transformer.
DIMENSIONS 1.065 (27.1)
In inches and (millimeters) 010 000 1.437 (36.5) 0.4 0.0 .125 .625 (15.9)
.656 (16.7) 1.687 (42.8) 1.430 (36.3)
1.593 (40.5)
Horizontal centerline of cylinder (A-R 4500 .125 series deadlatch) (3.2)
2.60 010 reverse 000 action .625 only 1.437 (16.7) (66.0) 0.3 (36.5) 010 1.50 000 (38.1) 3.375 dim. 0 0.4 2 (85.7) 0.0 7.937 (201.6) 2.468 (62.7)
156R (TYP 4 PLCS) (4.0) 0.10 000 0.15 000 1.625 (41.3) 7.942 0.4 (201.7) 0.4 0.0 0.0